Home > Temperature Control System > STE series Infrared

[Return Home] [Go Back]

STE series Infrared

Product Abstract:

Main suitable for the quenching, hardening application and forging application. STE series main for hardening, quenching and forging application, this is main through set the upper limit temperature and lower limit temperature to contorl.


wechat:Joanna8608
Chat online wechat:Joanna8608
Product Description

Main suitable for the quenching, hardening application and forging application. STE series main for hardening, quenching and forging application, this is main through set the upper limit temperature and lower limit temperature to contorl. For example: if you need hardening temperature is 800C, at this time you will set upper limit temperature is 800C, the lower limit temperature is 750C, so that when the heating temperature reach to 800C, the induction heating machine will stop it. When the workpiece lower 750C, the machine will heat again.
This series easy to connect to the induction heating machine, just let's the infrared wire connect to the our induction heating machine's switch foot signal interface, that's can control our induction heating machine.

Use the machine's main and auxiliary hot interface can control induction heating machine, stop heating when the workpiece is heated to the upper limit temperature – begin to heat when workpiece is below the lower limit temperature , that operating cycle control the workpiece temperature within the upper and lower limit temperature , automatic temperature control , and timing heating , constant temperature heating time.

Also use the machine's main and auxiliary hot interface can respectively control two heat sources, to achieve three works temperature control , or other functions ( according to customer special requirements to set )

Features?
1 Relay switch signal output, switch current signal output, two models as options.

Relay switch output mode , the signal output device is reed relay, characterized can bear high voltage, withstand big current, string directly into the contactor control coil loop ,common use.

Switch current output mode , ( non-contact output way ) , the output signal standard is set to 12V 50MA ( or in connection according to customer requirements ) switch voltage signal , used for directly drive the solid-state relays, non-contact switch , due to the response of the solid-state relay fast , and it could get the best situation.

2 Automatic delay timer start way options
The machine automatically delay start timer , there are two ways: one is start the machine and start the timer at the same time, the other is : workpiece heated to the upper limit setting temperature begin to timing, , selected by the switch on the front panel , suitable for quenching, hardening and so on.

3 Automatic delay time scale selection
Factory standard full scale of 9.9 seconds and 99 seconds , selected by the switch on the front panel , the other scale is set according to customer requirements

4 Fiber optic sensing
Since the detector adapt to the ambient temperature is below 75 ° C , the use of fiber optic sensing . Detector placed in the main part , the probe tolerance to adapt to high temperatures and strong electromagnetic interference environment

5 Fully coaxial laser sighting
Laser direct measurement position and with the actual testing point is fully same , they can ON or OFF at any time. The laser sighting switch without any operation , laser sighting will automatically enter turned off , and in order to reduce the power consumption , the factory setting is 30 seconds.

6 Easy to operate
Upper limit temperature and lower limit temperature, time set by the respective plus↑ less ↓ key to set, and keep continue display, but should remember the lower limit temperature should be can not higher than upper limit temperature. When the upper and lower limit is same, up the lower limit temperature unless, and also down the upper temperature, the lower limit temperature down automatic at the same time. If press temperature difference delete one time, lower limit temperature =upper limited temperature automatic.

Parameter


Mode

Temperature range

Structure  model

STE280

250-800 ?

Line fiber-optic thermometer

STE412

400-1200 ?

Line fiber-optic thermometer

STE716

700-1600 ?

Line fiber-optic thermometer

STE1020

1000-2000 ?

Line fiber-optic thermometer

STE1527

1500-2700

Line fiber-optic thermometer



Voltage: 220VAC-240VAC Power consumption < 10W
Distance coefficient :75:1
Repeatability precision: 1 ?
Fiber length : 1.4M ( standard)
Time scale : 9.9 seconds , 99 seconds as option, others please according to request to set.
Timing start : start the machine start timing or heated to the set temperature starts timing as options
Fully coaxial laser sighting : precise targeting, any switch , such as laser sighting enable 30 seconds laser sighting switch without any operation , will automatically turn off (30 seconds for the standard set ) , others requirements according to customer to set.
Working temperature: Host ≤ 50 ? Humidity : 10% -80% Fiber - optic probe: temperature ≤ 150 ° C Humidity : 10% -80%
Dimension: Main part 190 ( L) x 240 ( W ) × 115mm ( H) mm, fiber optic probe : diameter 20 x 90mm

Related Products
Ultrahigh Frequency Induction
High Frequency Induction Heating Machine
Super Audio Induction Heating
Medium Frequency Induction Heating Machine
Hot Sale Induction Heating Machine
-
Double Transfromer connect one Main Part
-
Hand type Connection Induction Heating Machine
-
Special Induction Heating Machine
Machine Line
-
Forging Furnace
-
Quenching Machine Line
Melting Furnace
-
Medium Frequency Melting Furnace
-
Small melting furnace
Medium Frequency Induction Power Supply
Water Cooling System
-
Chiller
-
Closed Cooling Tower
-
Open Cooling Tower
Temperature Control System

Contact Us

wechat:Joanna8608
Chat online